²úÆ·Ãû³Æ£º°Í¹Ì 543790 ToxiVision µ¥Í¨µÀÆøÌå¼ì²âÒÇ¡¾Í£²ú¡¿
ÉÌÆ·¼ò½é£º
ToxiVision ʹÓüò±ã,ÐÔÄÜÓÅÔ½,¼Û¸ñʵ»Ý,ÓÐЧÌá¸ßÄúµÄ¹¤×÷ЧÂÊ
¿¹ÉäƵ¸ÉÈÅ
ÌØÊâµÄÉäƵ¸ÉÈÅ·À»¤ÆÁ¿ÉÒÔµÖ¿¹Ë«Â·ÉäƵÒÔ¼°ÆäËüµç×Ó×°ÖõĸÉÈÅ£¬¿¹ÉäƵ¸ÉÈÅÄÜÁ¦´ï40V/m¡£¿ÉÒÔÔÚ¸ü¹ãÀ«µÄÁìÓòÓ¦Óá£
ÏÔʾÆÁµÄ³ß´ç
ÏÔʾÆÁ·Ç³£´ó£¬¼¸Ó¢³ßÖ®ÍⶼÄÜ¿´Çå¡£
¼á¹Ì
¶Æ¸õµÄÍâ¿Ç¿ÉÒÔµÖ¿¹¸¯Ê´ÐÔÆøÌ壨ÈçH2S£©¡£ToxiVision¾¹ýÕæ¿Õ²âÊÔ£¬È·±£·ÀË®µÈ¼¶´ïµ½IPX7¼¶
µ¥¼ü²Ù×÷
¼´Ê¹´÷×ű¿ÖصÄÊÖÌ×£¬Ò²ºÜÈÝÒ×ÓÃÕâ¸ö´óµÄµ¥¼ü½øÈëËùÓй¦ÄÜ
УÑé
µ¥¼ü²Ù×÷³¬ºõÑ°³£µÄ¿ìºÍÈÝÒ×
The ToxiVision is simple to use and will save you time and money through specially designed premium features
RFI protection
The special RFI shielding prevents operating interference from two-way radios and other electronic devices providing RFI immunity to 40v/m. This allows proper operation in a wider range of environments.
Display size
The display is very large and can be seen easily from several feet away.
Ruggedness
The chrome metal-plated case makes the Toxi Vision resistant to corrosive gases (e.g., H2S) The Toxi Vision is also vacuum-tested to ensure water tightness and has a rating of IPX7.
One -button operation
The large, single button makes for easy access to all functions,even when wearing bulky gloves.
Calibration
An incredibly quick and easy one-button process.
¼¼Êõ²ÎÊý£º
³ß´ç(³¤x¿íx¸ß) | 8.9x6.4x3.25 cm |
ÖØÁ¿ | 190g |
±¨¾¯ | ³ö³§É趨Á½¸ö±¨¾¯µã£¨Ã¿ÖÖ̽ͷ²»Í¬£¬¿Éͨ¹ýRS232¸ü¸Ä£© |
ÉùÒô±¨¾¯ | Ë«Éùµ÷½»ÌæÃùÏ죬92·Ö±´ |
·¢¹â±¨¾¯ | ºìÉ«·¢¹â¶þ¼«¹Ü |
ÏÔʾÆÁ±³¾°µÆ | Óð´¼ü¿ªÆô |
ѡװµÄÕñ¶¯±¨¾¯ | ÓÃÓÚÔëÒôºÜ´óµÄ»·¾³ |
°²È«ÉÁ˸ | É趨ºó£¬·¢¹â¶þ¼«¹Üÿ·ÖÖÓÉÁ˸һ´Î£¬Ö¤Ã÷ÒÇ±í´¦ÓÚ¹¤×÷״̬ |
¿ØÖÆ | µ¥¼üУÑé |
Íâ¿Ç | ¶Æ¸õABS£¬·ÀÉäƵ¸ÉÈÅÄÜÁ¦´ï40V/m |
Ƥ´ø¼Ð | ¹Ì¶¨ÓÚÒDZíÉϵÄƤ´ø¼Ð |
µç³ØʹÓÃʱ¼ä | 4000СʱÒÔÉÏ£¨2½Ú5ºÅ¼îÐÔµç³Ø£© |
ÄÍÓÃÐÔ | ·ûºÏIPX7·ÀË®µÈ¼¶ |
ÏÔʾ | ³¬´óÒº¾§ÏÔʾÆÁ |
±ê×¼¸½¼þ | УÑéÊÊÅäÆ÷ºÍÈí¹Ü |
STEL(¶Ìʱ±©Â¶Æ½¾ùÖµ)/TWA(ʱ¼ä¼ÓȨƽ¾ùÖµ) | ͨ¹ýRS232µçÀ¿ÉÑ¡Ôñ¿ªÆô |
TECHNICAL SPECIFICATIONS
Dimensions | 3 1/2¡±(8.9CM)x2 1/2¡± (6.4CM)x1 1/4¡± (3.25CM) |
Weight | 6.7oz.(190g) |
Alarms | Two factory-set alarm levels(different for each sensor;can be changed thru RS232) |
Audible Alarm | Loud warbling two-tone alarm rated at 92 dBA |
Visual Alarm | Bright Red LED alarm |
Display backlight | Activates with button |
Optional Vibrator alarm | For high noise environments |
Security Flash | LED falshes once per minute to verify instrument operation when set |
Controls | One button calibration |
Housing Chrome | Metal plated,RFI resistant ABS with immunity to 40V/m |
Clip Built | In steel clip |
Battery Life | Up to 4000hours(2 disposable AA alkaline batteries) |
Durability | Meets IPX7 water standard |
Display | Oversized Liquid Crystal Display |
Standard Accessories | Calibration adapter and hose,operators guide |
STEL/TWA |
Optionally enabled via RS232 cable |
¶©»õºÅ£º
ToxiVision »úÐÍ
¶©»õºÅ | º¬Ì½Í· |
54-37-90 | O2 |
54-37-01 | CO |
54-37-02 | H2S |
54-37-80A | LEL¼îÐÔµç³Ø |
54-37-80N | LEL³äµçµç³Ø |
ToxiVision Åä¼þ
¶©»õºÅ | ÃèÊö |
54-38-06 | ÊÖ¶¯²ÉÑù±Ã |
ToxiVision ̽ͷ
¶©»õºÅ | ÃèÊö | ¼ì²â·¶Î§ | ¼ì²â¾«¶È |
54-39-90 | O2 | 0-30%/VOL | 0.1%VOL |
54-39-01 | CO | 0-1000 PPM | 1PPM |
54-39-02 | H2S | 0-200 PPM | 1PPM |
Ïà¹Ø²úÆ·ËÑË÷>>°Í¹Ì Multi Vision ÃܱտռäÆøÌå¼ì²âÒÇ °Í¹Ì PhD Lite ÃܱտռäÆøÌå¼ì²âÒÇ